Vue de la page 4
SS control SyStemS
5
ProXImIty card reader locKS
PROXIMITY CARD READER LOCKS
SPECIFICATIONS
The Stanley OMNILOCK PDV Proximity Card Reader
systems offer the combination of the industry’s most
widely-accepted HID proximity technology and the proven
electronic superiority of Stanley OMNILOCK. The PDV
Systems provide all of the superior features and quality that
you have come to expect from Stanley OMNILOCK.
Capacity of 2000 individual users per door
Audit trail up to 50,000 events (optional key-by-pass
detection)
 • The OMNILOCK Facility Manager, a Microsoft
Windows
9X/2000/NT/XP compatible program, runs on a desktop
or laptop computer
 • The OMNILOCK Data Link, a Microsoft
Windows
PDA
compatible program, runs on a handheld PocketPC and
transfers data between the OMNILOCK OFM database
and OP2000 System Lock – NO plug-ins or laptops at
the door!
 • The OP2000 System Lock consists of a control module
coupled to a Grade 1 lockset
 • Access granted via Proximity card (most bitpatterns
accepted), Keypad Code, or Card or Code plus PIN
 • Flash ROM facilitates lock software upgrades via
infrared communication– NO PCBs need to be
changed when software is upgraded!
 • Password protected network-compatible software
 • ‘AA Battery-powered (100,000 operations)
 • Audit records user identity, date and time
 • Time schedule controls access for 8 user groups
 • Full electronic and electro-mechanical diagnostics may
be run without removing lock from the door
 • Cylindrical locks install in a standard ANSI 156.2
(formerly 161) door preparation
 • Electronics easily retrofit to existing OM100, OM300,
OM500, or OM2000 OMNILOCK systems!
ID TYPES
Proximity Card 26-bit, 32-bit, 33-bit, 35-bit Corporate 1000, or
37-bit formats, Keypad ID 4 to 10 digits in length, and/or PIN
lengths of 3 to 6 digits long.
PROGRAMMER ID
Uploads and downloads all programming data, Changes
Access Levels, Enables User G
roups, and may run
Diagnostics. Privileges are assignable. Quantity as required.
MANAGER ID
Enables or disables User Groups or sets Access Levels at
doors, privileges are assignable.
GENERAL USER ID
Allows access when access level is at ID Required and user
group is enabled. Quantity 2000 users less masters and
managers.
SERVICE ID
Allows limited use to service personnel-PIN required at all
times. Quantity as required.
ACCESS LEVELS
Level 2: Free passage – unlocked.
Level 3: Remains unlocked after first valid ID
Level 4: Remains unlocked after first valid ID and PIN
Level 5: Enrolled ID required (ID code or prox card)
Level 6: Enrolled ID and PIN required
Level 7: Facility ID card required
Level 8: Lockout (Manager or Programmer ID allowed only
if privileges have been assigned)
AUDIT LOG
Transactions: Retains last 50,000 events, whether keypad
code, prox card or fob, key bypass detection, antitamper,
attempt by unauthorized user, remote switch operation, or
time scheduled event.
Events Audited: Ten separate events are recorded
Record Format: Date, Time, Identity, Event
TIME SCHEDULE
Sets Access Level and controls access by user
groups automatically at selected preprogrammed
times. May be preprogrammed for holiday scheduling.
Capacity: 144 scheduled events per day, 32 holiday
periods
User Groups: 8
INTERNAL CLOCK
Resolution: 1 minute with leap
year correction
Daylight Savings:
Automatic or manual
corrections